If the voltage is still less than +14.4 V dc after
recharging, replace the battery.
4. If the voltage is more than +14.4 V dc, measure the
resistance between battery terminals 4 and 5. The
resistance must be 4 to 30 K .
If the resistance is not correct, replace the battery
pack. If the resistance is correct, replace the system
board.
Checking the backup battery
Do the following:
1. Power off the computer, and unplug the ac adapter
from it.
2. Turn the computer upside down.
3. Remove the battery pack (see “1010 Battery pack” on
page 76).
4. Remove the backup battery (see “Checking the battery
pack” on page 47).
5. Measure the voltage of the backup battery. See the
following figure.
Red (+)
Black (-)
Wire Voltage (V dc)
Red +2.5 to +3.2
Black Ground
v If the voltage is correct, replace the system board.
v If the voltage is not correct, replace the backup battery.
v If the backup battery discharges quickly after
replacement, replace the system board.
Checkout guide
48 MT 2369/2370/2371/2372/2382/2386

Table of Contents

Other manuals for IBM THINKPAD X40

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM THINKPAD X40 and is the answer not in the manual?

IBM THINKPAD X40 Specifications

General IconGeneral
BrandIBM
ModelTHINKPAD X40
CategoryDesktop
LanguageEnglish

Related product manuals