Intermittent  problems 
Intermittent  system  hang  problems  can  be  due  to  a  variety 
of  causes  that  have  nothing  to  do  with  a  hardware  defect, 
such  as  cosmic  radiation,  electrostatic  discharge,  or 
software  errors.  FRU  replacement  should  be  considered 
only  when  a  problem  recurs. 
When  analyzing  an  intermittent  problem,  do  the  following: 
1.  Run  the  diagnostic  test  for  the  system  board  in  loop 
mode  at  least  10  times. 
2.  If  no  error  is  detected,  do  not  replace  any  FRUs. 
3.  If  any  error  is  detected,  replace  the  FRU  shown  by  the 
FRU  code.  Rerun  the  test  to  verify  that  no  more  errors 
exist.
Undetermined  problems 
If  the  diagnostic  tests  did  not  identify  the  adapter  or  device 
that  has  failed,  if  wrong  devices  are  installed,  or  if  the 
system  simply  is  not  operating,  follow  these  procedures  to 
isolate  the  failing  FRU  (do  not  isolate  FRUs  that  have  no 
defects). 
Verify  that  all  attached  devices  are  supported  by  the 
computer. 
Verify  that  the  power  supply  being  used  at  the  time  of  the 
failure  is  operating  correctly.  (See  “Power  system 
checkout”  on  page  46.) 
1.  Power  off  the  computer. 
2.  Visually  check  each  FRU  for  damage.  Replace  any 
damaged  FRU. 
3.  Remove  or  disconnect  all  of  the  following  devices: 
a.  Non-IBM  devices 
b.  Devices  attached  to  the  port  replicator 
c.  Printer,  mouse,  and  other  external  devices 
d.  Battery  pack 
e.  Hard  disk  drive 
f.  External  diskette  drive 
g.  DIMM 
h.  CD-ROM  and  diskette  drive  in  the  Ultrabay 
i.  PC  Cards
4.  Power  on  the  computer. 
5.  Determine  whether  the  problem  has  changed. 
6.  If  the  problem  does  not  recur,  reconnect  the  removed 
devices  one  at  a  time  until  you  find  the  failing  FRU. 
7.  If  the  problem  remains,  replace  the  following  FRUs  one 
at  a  time  (do  not  replace  a  nondefective  FRU): 
a.  System  board 
b.  LCD  assembly
Symptom-to-FRU  index  
70  MT  2369/2370/2371/2372/2382/2386