26
Operating Mode (continued)
Program Mode
In this mode, the program function is on (PROG displays), and the thermostat will
automatically be controlled by the set program. Program mode can function with Heat
mode, Cool mode, Cool and Heat mode, or OFF mode (for Programmable fan option
only).
Press the button to enter and exit program mode.
Program Mode Hold
The program schedule can be overridden by changing the set temperature ( or ). After 2 hours, the
program schedule will automatically be resumed. To return to the program schedule manually, press the
button twice.
The time and day of the week must be set for your program schedule to operate correctly.
1. Verify thermostat is in non-programmable mode (use the button to exit prog mode).
2. Press and release button until OFF mode displays.
3. Press the button in for 6 seconds.
4. Press the or button to adjust the time.
5. Press the button while the time is displayed. The display shows the day
currently set on the thermostat (1=Monday, 2=Tuesday, etc).
6. Press the or button to set the correct day of the week that today is.
Note: Press the button in for 5 seconds to lock values into memory or
press the button once to enter programming.
Setting the Time and Day of the Week

Other manuals for ICM Controls SC 3801

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ICM Controls SC 3801 and is the answer not in the manual?

ICM Controls SC 3801 Specifications

General IconGeneral
BrandICM Controls
ModelSC 3801
CategoryThermostat
LanguageEnglish

Related product manuals