4-5 SET MODE ADJUSTMENT
ENTERING
ADJUSTMENT
SET MODE
Id APC
FILTER
CALIBRATION
POWER
METER
(14 MHz)
TUNING
POWER
(14 MHz)
(50 MHz)
POWER
METER
(145 MHz)
POWER
METER
(430 MHz)
ALC METER
SWR METER
ADJUSTMENT ADJUSTMENT CONDITION DISPLAY OPERATION
• Enter adjustment set mode:
1 Turn power OFF.
2 Terminate the [REMOTE] jack with a
3.5(d) mm mini-plug.
3 While pushing [P.AMP/ATT] and
[TUNE/CALL], turn power ON.
• Connect an RF power meter to [ANT1]
connector.
• Connect a DC ammeter between the DC
power supply and transceiver’s DC power
socket (P601 on the PA unit).
• Transmit using an external PTT switch.
• Connect an RF power meter to [ANT1]
connector.
• Connect an RF power meter to [ANT1]
connector.
• Transmit using an external PTT switch.
• Transmit using an external PTT switch.
• Connect an RF power meter to [ANT1]
connector.
• Transmit using an external PTT switch.
• Transmit using an external PTT switch.
• Connect an RF power meter to [ANT2]
connector.
• Transmit using an external PTT switch.
• Transmit using an external PTT switch.
• Connect an RF power meter to [ANT2]
connector.
• Transmit using an external PTT switch.
• Transmit using an external PTT switch.
• Connect an RF power meter to [ANT1]
connector.
• Connect an audio generator to [MIC] con-
nector and set as :
Level : 1.5 kHz/30mV
• Transmit using an external PTT switch.
• Connect a 50 Ω dummy load or power
meter to [ANT1] connector.
• Connect a 50 Ω dummy load or power
meter to [ANT1] connector.
1
1
1
1
2
1
2
1
2
1
2
1
1
2
SET IdAPC
GO FILTER CAL
SET 90 %
SET 50 %
SET TUNE Po
SET TUNE Po
SET 90 %
SET 50 %
SET 90 %
SET 50 %
ALC START
SWR 1 LOAD
SWR 2 LOAD
Push [F-3 (TX)] to enter the TX
adjustment setting mode.
Then advance to the following set-
ting, or push [UP]/[DN] to scroll the
display.
Set a total current at 15 A by adjust-
ing R1125 on the MAIN board.
Push [MENU] to set the "SET
IdAPC" after returning receiving con-
dition.
Push and hold [MENU (GO)] to
make the calibration.
• Transceiver transmits for a while.
Set to 90 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 50 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 10 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 10 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 45 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 25 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 18 W using [MAIN DIAL], then
push [MENU] while transmitting.
Set to 10 W using [MAIN DIAL], then
push [MENU] while transmitting.
Push and hold [MENU] to set ALC
reference level while transmitting.
Push [MENU] to set SWR reference
level.
Push [MENU] to set SWR2 level.
• The display returns to the same as