19
CONTROL COMMAND
19-11
Remote control (CI-V) information (Continued)
• Codes for CW message contents
Command : 17 Up to 30 characters
To send CW messages, use the following character
codes.
Character ASCII code
0–9 30–39
A–Z 41–5A
a–z 61–7A
/ 2F
? 3F
. 2E
− 2D
, 2C
: 3A
Character ASCII code
’ 27
( 28
) 29
= 3D
+ 2B
” 22
@ 40
Space 20
L“FF” stops sending CW messages.
L “^” is used to transmit a string of characters with no
inter-character space.
• RIT frequency settings
Command : 21 00
10 Hz: 0–9
100 Hz: 0–9
1 Hz: 0–9
1 kHz: 0–9
XXXX XX
00: + (plus)
• Repeater tone/tone squelch frequency settings
Command : 1B 00, 1B 01
100Hz digit: 0–2
10 Hz digit: 0–9
1 Hz digit: 0–9
0.1 Hz digit: 0–9
Fixed digit: 0*
Fixed digit: 0*
q*
00X
we
X
*Not necessary when setting a frequency.
• UTC Offset setting
Command : 1A 05 0096
X
Shift direction
00: + (plus)
01: − (minus)
Offset time
XXX XX
• Selected or unselected VFO frequency settings
Command: 25
X X X X X X X X X X 0 0
00: Selected VFO
01: Unselected VFO
Operating frequency data
• Selected or unselected VFO’s operating mode
and lter settings
Command: 26
Both data and lter settings can be skipped. In that
case, “DATA OFF” and the default lter setting of the
operating mode are automatically selected.
X X X X X XX X
q
e
w
Data mode setting
00: Selected VFO
01: Unselected VFO
q Operating mode w Data mode setting
e Filter
setting
00: LSB 05: FM 00: Data mode OFF 01: FIL1
01: USB 07: CW-R 01: Data mode ON 02: FIL2
02: AM 08: RTTY-R 03: FIL3
03: CW
04: RTTY