REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd�
Sub cmd� Data Description
1A* 05 SCOPE > SCOPE SET
01 86 00 ~ 02 Send/read the CENTER Type
Display setting
( 00=Filter Center,
01=Carrier Point Center,
02=Carrier Point Center (Abs� Freq�))
01 87 00/01 Send/read the Marker Position
(FIX Type/SCROLL Type) setting
(00=Filter Center, 01=Carrier Point)
01 88 00/01 Send/read the VBW setting
(00=Narrow, 01=Wide)
01 89 00 ~ 03 Send/read the Averaging setting
(00=OFF, 01=2, 02=3, 03=4)
01 90 00/01
Send/read the Waveform Type setting
(00=Fill, 01=Fill+Line)
01 91 See p� 21� Send/read the Waveform Color
(Current) setting
01 92 See p� 21� Send/read the Waveform Color
(Line) setting
01 93 See p� 21� Send/read the Waveform Color
(Max Hold) setting
01 94 00/01
Send/read the Waterfall Display setting
(00=OFF, 01=ON)
01 95 00 ~ 02
Send/read the Waterfall Speed setting
(00=Slow, 01=Mid, 02=Fast)
01 96 00 ~ 02 Send/read the Waterfall Size
(Expand Screen) setting
(00=Small, 01=Mid, 02=Large)
01 97 00 ~ 07
Send/read the Waterfall Peak Color
Level setting
(00=Grid1 ~ 07=Grid8)
01 98 00/01 Send/read the Waterfall Marker
Auto-hide setting
(00=OFF, 01=ON)
01 99 See p� 21� Fixed Edges > 144M >
Send/read the No�1 setting
02 00 See p� 21� Fixed Edges > 144M >
Send/read the No�2 setting
02 01 See p� 21� Fixed Edges > 144M >
Send/read the No�3 setting
02 02 See p� 21� Fixed Edges > 144M >
Send/read the No�4 setting
02 03 See p� 21� Fixed Edges > 430M >
Send/read the No�1 setting
02 04 See p� 21� Fixed Edges > 430M >
Send/read the No�2 setting
02 05 See p� 21� Fixed Edges > 430M >
Send/read the No�3 setting
02 06 See p� 21� Fixed Edges > 430M >
Send/read the No�4 setting
02 07 See p� 21� Fixed Edges > 1200M >
Send/read the No�1 setting
02 08 See p� 21� Fixed Edges > 1200M >
Send/read the No�2 setting
02 09 See p� 21� Fixed Edges > 1200M >
Send/read the No�3 setting
02 10 See p� 21� Fixed Edges > 1200M >
Send/read the No�4 setting
Cmd�
Sub cmd� Data Description
1A* 05 SCOPE > SCOPE SET
02 11 See p� 21� Fixed Edges > 2400M >
Send/read the No�1 setting
02 12 See p� 21� Fixed Edges > 2400M >
Send/read the No�2 setting
02 13 See p� 21� Fixed Edges > 2400M >
Send/read the No�3 setting
02 14 See p� 21� Fixed Edges > 2400M >
Send/read the No�4 setting
02 15 See p� 21� Fixed Edges > 5600M >
Send/read the No�1 setting
02 16 See p� 21� Fixed Edges > 5600M >
Send/read the No�2 setting
02 17 See p� 21� Fixed Edges > 5600M >
Send/read the No�3 setting
02 18 See p� 21� Fixed Edges > 5600M >
Send/read the No�4 setting
02 19 See p� 21� Fixed Edges > 10G >
Send/read the No�1 setting
02 20 See p� 21� Fixed Edges > 10G >
Send/read the No�2 setting
02 21 See p� 21� Fixed Edges > 10G >
Send/read the No�3 setting
02 22 See p� 21� Fixed Edges > 10G >
Send/read the No�4 setting
AUDIO > AUDIO SCOPE SET
02 23 00/01 Send/read the FFT Scope
Waveform Type setting
(00=Line, 01=Fill)
02 24 See p� 21� Send/read the FFT Scope
Waveform Color setting
02 25 00/01 Send/read the FFT Scope
Waterfall Display setting
(00=OFF, 01=ON)
02 26 See p� 21�
Send/read the Oscilloscope
Waveform Color setting
VOICE
02 27 00 00 ~ 02 55 Send/read the TX LEVEL setting
(
00 00=0% ~ 02 55=100%)
02 28 00/01
VOICE TX SET >
Send/read the Auto Monitor setting
(00=OFF, 01=ON)
02 29 01 ~ 15
VOICE TX SET >
Send/read the Repeat Time setting
(01=1sec ~ 15=15sec)
KEYER > KEYER 001
02 30 00 ~ 04
Send/read the Number Style setting



02 31 01 ~ 08
Send/read the Count Up Trigger setting
(01=M1 ~ 08=M8)
02 32 00 01 ~ 99 99 Send/read Present Number setting
(00 01=1 ~ 99 99=9999)
KEYER > CW-KEY SET
02 33 00 00 ~ 02 55 Send/read Side Tone Level setting
(
00 00=0% ~ 02 55=100%)