67
7
DSC OPERATION
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
D Alarm
Set the Alarm function ON or OFF, depending on the Cat-
egory or Status.
q Enter “ALARM”
in the DSC Settings menu
.
MENU DSC Settings Alarm
(Push [MENU].)
(Rotate Dial, then push [ENT].)
w Rotate Dial or push [Y]/[Z] to select the status, then push
[ENT].
• Push [BACK] to return to the previous screen.
Safety, “Routine,” “Warning, “Self-Terminate” and “Discrete” are
selectable. (default: ON )
e Rotate Dial or push [Y]/[Z] to set the Alarm setting to “ON”
or “OFF.
r Push [EXIT] to return to the normal operating mode.
D Channel 70 Squelch level
Set the squelch level on Channel 70.
The transceiver has 11 squelch levels between 1 (loose
squelch) and 10 (tight squelch) and OPEN.
OPEN is completely open.
q Enter “CH 70 SQL LEVEL
in the DSC Settings menu
.
MENU DSC Settings CH 70 SQL Level
(Push [MENU].)
(Rotate Dial, then push [ENT].)
w Rotate Dial or push [Y]/[Z] to adjust the squelch level until
the noise just disappears, then push [ENT].
• Push [BACK] to cancel and return to the DSC Settings menu.
(default)
e Push [EXIT] to return to the normal operating mode.