ADJUSTMENT ITEM ADJUSTMENT CONDITION OPERATION VALUE
ATTENUATION
[HF ATT 6dB]
• Set the SG as;
Frequency : 14.1515 MHz
Level : +40 dBu
Push [F-7] key. (Automatic
adjustment)
[HF ATT 12dB] Push [F-7] key.
[HF ATT 24dB] Push [F-7] key.
ROOFING FILTER LOSS
[HF FIL 3k LOSS]
• Set the SG as;
Frequency : 14.1515 MHz
Level : +40 dBu
Push [F-7] key. (Automatic
adjustment)
[HF FIL 6k LOSS] Push [F-7] key.
[HF FIL 50k LOSS] Push [F-7] key.
ADJUSTMENT ITEM ADJUSTMENT CONDITION OPERATION VALUE
TUNED LPF
[Tuned LPF LOW]
• Set the SG as;
Frequency : 1057.4215 MHz
Level : +50 dBu
Modulation : None
Rotate [MAIN DIAL] to adjust the AF
output level.
Push [F-7] key.
Minimum AF
level
[Tuned LPF MID1] • Set the SG as;
Frequency : 1307.4215 MHz
Level : +40 dBu
Rotate [MAIN DIAL] to adjust the AF
output level.
Push [F-7] key.
[Tuned LPF MID2]
(Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.
Push [F-7] key.
“C7”
[Tuned LPF HIGH]
(Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.
Push [F-7] key.
“D7”
TUNED HPF
[Tuned HPF LOW] (Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.
Push [F-7] key.
“00”
[Tuned HPF MID1]
(Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.Push [F-7] key.
“05”
[Tuned HPF MID2]
(Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.Push [F-7] key.
“10”
[Tuned HPF HIGH]
(Same as above)
Rotate [MAIN DIAL] to set the adjustment
value.Push [F-7] key.
“80”
4-5 RECEIVE ADJUSTMENTS (VHF and UHF) [RX-V/U]
• Push [F-2•RX V/U] key to select RX V/U ADJUSTMENT.
• Connect an AC milivoltmeter to the [EXT-SP] jack.
• Connect an SG to [ANT1/HF ANT3], and set as;
Modulation : None
NOTE: HOLD the adjustment condition (SG level and frequency etc.) until next ADJ item is displayed.
NOTE: HOLD the adjustment condition (SG level and frequency etc.) until next ADJ item is displayed.

Other manuals for Icom IC-R9500

Related product manuals