5 - 7
5-4 RECEIVE ADJUSTMENTS
1) Select an adjustment item (band) using
/
.
2) Set the SSG as specifi ed (frequency, deviation and output level), and then push to automatically adjust.
ADJUSTMENT
ADJUSTMENT
ITEM
OPERATION VALUE
RECEIVE
SENSITIVITY
NOTE:
RECEIVE SENSITIVITY must be adjusted before “S-METER. Otherwise, S-METER will
not be adjusted properly.
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector, and then set it as;
Frequency : (Displayed on the function display)
Level : –10 dBµ (–117 dBm)
Modulation : 1 kHz
Deviation : 3.5 kHz
Push
.
(Automatic
adjustment)
400.02 MHz
[UTL] 2
435.02 MHz
[UTM] 3
478.95 MHz
[UTH] 4
S-METER NOTE:
RECEIVE SENSITIVITY must be adjusted before “S-METER and “S-METER S3 LEVEL. Otherwise,
S-METER and “S-METER S3 LEVEL will not be adjusted properly.
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set it as;
Modulation : 1 kHz
Deviation : 3.5 kHz
S0 level
[USO]
2 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –10 dBµ (–117 dBm)
Push .
(Automatic
adjustment)
S3 level
[US3]
3 • Set the SSG as;
Level : –6 dBµ (–113 dBm)
Full scale
[USF]
4 • Set the SSG as;
Level : +10 dBµ (–97 dBm)
SQUELCH
[SQL]
1 1) Set the power supply voltage to 7.4 V.
2) Connect an SSG to the antenna connector and set as;
Modulation : 1 kHz
Deviation : 1.75 kHz
[FM]
2 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : OFF
Push .
(Automatic
adjustment)
[
FM-N
]
3 • Set the SSG as;
Frequency : (Displayed on the function display)
Level : –24 dBµ (–131 dBm)
; This output level of a standard signal generator (SSG) is indicated as SSG’s open circuit.