5 - 4
SQUELCH
5-3 RECEIVER ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE ADJUSTMENT
UNIT LOCATION
Audio signal
disappears.
1
2
Operating channel : Ch 04
Connect an SSG to J1 on the RF unit
and set as:
Frequency : 446.04375 MHz
Level : 0.14 µV*
(–124 dBm)
Modulation : OFF
Receiving
• Set an SSG as :
Level : OFF
Receiving
Front
panel
Internal speaker
Push and hold
[MODE] and
[DOWN] keys for
1 sec.
Verify