ICON STAGE USER MANUAL
Blade 2 Rotation wheel Er
(Blade 2 Rotation wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade 2 Rotation - movement is not located in the default position
after the reset.
Blade 3 wheel Er
(Blade 3 wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade 3 - movement is not located in the default position after the
reset.
Blade 3 Rotation wheel Er
(Blade 3 Rotation wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade 3 Rotation - movement is not located in the default position
after the reset.
Blade 4 wheel Er
(Blade 4 wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade 4 - movement is not located in the default position after the
reset.
Blade 4 Rotation wheel Er
(Blade 4 Rotation wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade 4 Rotation - movement is not located in the default position
after the reset.
Blade Rotation wheel Er
(Blade Rotation wheel_ error) This message will appear after the reset of the fixture if the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective
(or its driving IC on the main PCB). The Blade Rotation - movement is not located in the default position
after the reset.