ICP 9MPT - Wiring Diagram: *9 MPV075, 100 & 125(A2) 1 HP DC Blower Motor

ICP 9MPT
63 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Two- Stage Multi Position Furnace
Service
Manual
57
440 08 2002 02
AL WAYS CHECK CURRENT TECHENICAL SUPPORT MANUAL
Wiring Diagram (1 HP DC Blower Motor) *9MPV075, 100 & 125(A2)
12
30 SEC.
12
12
12
12
2 STAG
E
43
12
SING
LE STAGE
4
3
LIMIT
MAIN
12
1
*
2-STAGE
4
2 STAGE
P2
INTERNAL CIRCUIT BOARD WIRING
LOW VOLTAGE FIELD
LOW VOLTAGE FACTORY
LINE VOLTAGE FIELD
LINE VOLTAGE FACTORY
COLOR CODE
8
2
N
HUM
N
EAC
24V
N
HUM
ON
34
43
SETTING
FACTORY
4
60 SEC.
33
100 SEC.
4
HOT 115V-60HZ NEUTRAL
DANGER: ELECTRICAL SHOCK HAZARD
DISCONNECT BEFORE SERVICING
GND.
SWITCH
INTERLOCK
CONNECTION DIAGRAM
SWITCH
INTERLOCK
BOX
CONNECTION
FIELD
COOL OFF DELAY: 60 SEC
COOL ON DELAY: 5 SEC
1013375-B
SEE MANUALS FOR ADJUSTING SWITCHES FOR PROPER HEATING, COOLING & CIRCULATING SPEEDS.
S1
L1
EAC
CAPACITOR
(SOME MODELS)
N
LADDER DIAGRAM
60HZ
115V
3344
G
Y
G
R
W
1
W
2
G
Y
C
R
R
SWITCH
PRESSURE
LOW
3
2
3
8
7
+
VALVE
GAS
-
2
6
23
4
1
5
1
O
N
R
Y
4
BK
9
BK
HOT
8
5
W
6
51
GND
6
2
2
BL
7
3
NEUTRAL
84
3
1
Y
THERMOSTAT
SINGLE STAGE
R
R
Y
BL
BK
Y
W
W
BL
BK
IN
D
L
O
W
H
E
A
T
L
O
W
5A FUSE
W
2
W
1
G
BL
R
BR
Y
BK
C
G
G
Y
W1
R
W2
24V SECONDARY
115V PRIMARY
FAN CONTROL MODULE
12
140 SEC. 60 SEC.180 SEC.
43
12
1
8
FURNACE CONTROL
R
SWITCH
PRESSURE
HIGH
R
GAS VALVE
R
SWITCH
PRESSURE
LOW
MAIN LIMIT
BL
3
6
4
7
THERMOSTAT
2-STAGE
2
VALVE
GAS
5
R
N
BL
BL
N
SENSOR
1
2
3
4
L1
IGNITER
BK
W
+
2 STAGE
BK
P
BL
(LP MODELS ONLY)
SWITCH
LP PRESSURE
4
2
4
L1
H
E
A
T
H
I
IN
D
H
I
C
O
O
L
E
A
C
H
U
M
C
O
N
T
IN
D
IN
R
W
W
O
W
W
P1
W
MOTOR
INDUCER
M2
M1
W
L1
XFMR
O
L1
BK
BK
1
4
4
P1
2
1
5
3
7
4
6
5
3
6
9
1
W
1
Y
W2
G
TRANSFORMER
Y
W
L
IN
E
1
2
0
V
A
C
X
F
M
R
D
C
M
T
R
P1
COM
3
NEUTRAL
2
1
VAC
24
47
P
2
Y
2
C
R
(OPTIONAL)
HUMIDISTAT
W
G
1
2
3
4
Y
Y
W1
G
TRANSFORMER
HIGH
INDH
MOTOR
INDUCER
LO
INDIN
INDL
1
2
3
4
3
1
115V
R
R
COM
BR
24VAC
BR
5 A FUSE
24VAC
IGNITER
SENSOR
2 STAGE
-
+
-
S
H
IE
L
D
B
E
A
D
G
BL
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH TYPE AW M-105ÂșC WIRE OR EQUIV.
S
H
IE
L
D
B
E
A
D
1
1
5
V
H
O
T
J
U
M
P
E
R
, S
U
R
G
E
J
U
M
P
E
R
, S
U
R
G
E
1
1
5
V
N
E
U
T
R
A
L
J
U
M
P
E
R
, 1
1
5
V
J
U
M
P
E
R
, 1
1
5
V
DC MOTOR
CONTROL
*A
IR
F
L
O
W
D
IP
S
W
IT
C
H
E
S
TH
ERM
O
STA
T TYPE
HEA
T O
N DELAY
H
EAT OFF D
ELAY
R
O
LL
O
U
T
S
W
IT
C
H
1
T
O
3
IN
S
E
R
IE
S
D
E
P
E
N
D
IN
G
O
N
M
O
D
E
L
H
IG
H
P
R
E
S
S
U
R
E
S
W
IT
C
H
R
O
LL
O
U
T
S
W
IT
C
H
1 T
O
3
IN
S
E
R
IE
S
D
E
P
E
N
D
IN
G
O
N
M
O
D
E
L
C
A
P
A
C
IT
O
R
(S
O
M
E
M
O
D
E
LS
)
(HI VOLT FIELD)
COPPER
CONDUCTORS
ONLY
CIRCUIT BOARD
1
4
23
5
6
G
BL
Y
R
G
BL
Y
R
DC
BLOWER
MOTOR
5
4
3
2
1
10
9
8
7
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
6
7
8
MOTOR
BLOWER
DC
*A
IR
F
L
O
W
D
IP
S
W
IT
C
H
E
S
DC MOTOR
CONTROL
J
U
M
P
E
R
, 1
1
5
V
J
U
M
P
E
R
, 1
1
5
V
1
1
5
V
N
E
U
T
R
A
L
J
U
M
P
E
R
, S
U
R
G
E
J
U
M
P
E
R
, S
U
R
G
E
1
1
5
V
H
O
T
5
4
3
2
1
10
9
8
7
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
6
7
8
5
4
3
2
1
10
9
8
7
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
6
7
8
MOTOR
BLOWER
DC
*A
IR
F
L
O
W
D
IP
S
W
IT
C
H
E
S
DC MOTOR
CONTROL
J
U
M
P
E
R
, 1
1
5
V
J
U
M
P
E
R
, 1
1
5
V
1
1
5
V
N
E
U
T
R
A
L
J
U
M
P
E
R
, S
U
R
G
E
J
U
M
P
E
R
, S
U
R
G
E
1
1
5
V
H
O
T
L
P
P
R
E
S
S
U
R
E
S
W
IT
C
H
(LP
M
O
D
E
LS
O
N
LY
)
W
2
BLACK
BLUE
BROWN
GREEN
ORANGE
RED
WHITE
YELLOW
PURPLE
BK
BL
BR
G
O
R
W
Y
P
EAC + HUM: 0.8 A MAX. COMBINED
THERMOSTAT
1
2
NOTE: MOST VOLT METERS WILL READ 13-16 VOLTS TO
CHASSIS ON BOTH SIDES OF AN OPEN LIMIT OR PRESSURE
SWITCH IN THE RECTIFIED AC VOLTAGE CIRCUIT
RECTIFIED AC VOLTAGE FACTORY

Related product manuals