Forleftsidemountedcondensatetrap,connectthe3/4"ODrubber
hosewiththe90°bendtothelargedrainstubonthecondensate
trapandsecurewitha 3/4" clamp.
Route the hose to the drain stub on the bottom of the plastic transi-
tion box. Cut off excess hose and discard. Connect the hose to the
drain stub on the transition and secure with a 3/4" clamp.
For right side mounted condensate trap, connect the 3/4" OD rub-
ber hose with the 90 ° bend to the bottom of the plastic transition box
and secure with a 3/4" clamp.
Route the hose to the large drain stub on the condensate pump.
Cut off excess hose and discard. Connect the hose to the drain
stub on the condensate trap and secure with a 3/4" clamp.
Upflow Installations (Single Pipe & Direct Vent N9MP1 & N9MP2-A2 Models)
RIGHTSideVentinq NOTE: TRAP MUST BE PRIMED BEFORE OPERATION
DRAIN SIDE VIEW
Rotate
5° to t0°
}uilt-in channel will
be angled 5° to 10° als0.
Supply Air
Vent
Drain
Some Models
haveone
reesureswitch
PVCVent
25-24-05
For left aide or right aide mounted condenaate trap, the pres-
sure tap on the condensate trap MUST be connected to the unused
pressure tap located on the upper right hand corner of the plastic
transition box. Remove the plastic caps from the pressure taps on
the condensate trap and the plastic transition and connect with the
5/16" OD rubber hose. (See Figure 6 and Figure 7)
Connect the 5/8" OD rubber hose with the 90° bend to the lower
ipe
TrapConnection
Pointed OUT
Preassembte
andinsert
intofurnace
Representive drawing, some valves will vary.
drain stub on the vent fitting and secure with a 5/8" clamp.
Route the hose to the smaller drain stub on the condensate trap.
Cut off excess hose and discard. Connect the hose to the drain
stub on the trap and secure with a 5/8" clamp.
NOTE: Route hoses to the condensate trap with no kinking or bind-
ing for proper condensate drainage.
441 06 1039 00 - 9 -