NaviTEK NT 153800 Iss 1
User Guide Page 10
Getting started
Press the soft key DETECT (F1) and the tester will determine the mode of operation
dependent on the services detected.
The modes of operation that follow are available:
Modes of Operation
NaviTEK NT has two fundamental modes of operation –
Cable
When the tester is connected to a copper
cable
, with or without an active remote,
press the soft key DETECT (F1) to display
all options available from the Cable mode
screen (
Fig 6). When an active remote is
connected it will be shown on screen and
its identification number displayed. For a
full description of these options, see -
Tests menu description – Cable mode.
When the tester is connected to a
network/device, using either copper or fiber
cable, press the soft key DETECT (F1), to
display all options available from the Ethernet
mode screen (
Fig 7). For a full description of
these options see – Tests menu description –
Ethernet mode.
The detected services are PoE (802.3af/at.
standard), ISDN S, PBX and
Unknown. The IPv4 and IPv6 addresses
assigned to the tester are displayed (when