31
16
Fix the lower casing supports (pack IE 10 to IE 14) on the
framework using 1 bolt HM 8x25 + lock washer for each
support.
8229-EN-23
Fit the body insulation panels. Bear up the insulation by tying
each strap to the lower casing support at each side of the
boiler.
8229-EN-50 A
Loosen the screw
Body delivered pre-assembled
only: IMPORTANT
8229-EN-24 A
Viceroy GT Range - Installation
ASSEMBLY
15
Boiler Body insulation width
Front Rear
500 500 600 800 900
Viceroy GT 8 1 1
Viceroy GT 9 1 1 1
Viceroy GT 10 1 1 1
Viceroy GT 11 1 1 1
Viceroy GT 12 1 2 1
Viceroy GT 13 1 2 1
Viceroy GT 14 1 2 1
Pack IE10 IE13 IE14 IE11 IE12