Idexx Catalyst One Specifications

General IconGeneral
TypeVeterinary Chemistry Analyzer
Sample TypeWhole blood, serum, plasma, urine
Humidity10% to 85% non-condensing
ConnectivityUSB, Ethernet
Supported SpeciesCanine, Feline, Equine, Bovine
Weight22 lbs
Operating Temperature15°C to 30°C
Power Supply100-240 VAC, 50/60 Hz
DisplayTouchscreen
Sample Volume100 µL
Result Time8 minutes
Regulatory ComplianceCE

Summary

Preface

Safety Precautions

General guidelines for safe operation and handling of the analyzer.

Performance Precaution

Precautions to ensure optimal analyzer performance and accurate results.

Care of the Analyzer

Recommendations for maintaining the analyzer's condition and longevity.

Getting Started

IDEXX VetLab* Station Connectivity

Information on connecting the analyzer to the IDEXX VetLab Station.

Analyzer Status

Explanation of LED indicator colors and their meanings for analyzer status.

Responding to an Alert

Procedure for viewing and responding to alert messages from the analyzer.

Installing the Catalyst One Analyzer

Step-by-step guide for installing and connecting the Catalyst One analyzer.

Using the Catalyst One* Analyzer

Analyzing Samples

Description of four work flows for analyzing samples on the analyzer.

Slide Handling

Guidelines for handling CLIPs, panels, and slides during analysis.

Diluting Samples

Procedures and considerations for diluting samples for analysis.

Outside of Reportable Range Samples

Information on handling test values outside the reportable range.

Sample Preparation and Storage

Preparing Samples for Use on the Catalyst One Analyzer

Detailed steps for preparing whole blood and plasma samples.

To Prepare a Serum Sample

Step-by-step guide for preparing serum samples.

To Prepare a Urine Sample

Step-by-step guide for preparing urine samples.

Sample Inspection After Centrifugation

Guidelines for inspecting samples for hemolysis, icterus, and lipemia.

Sample Storage

Recommendations for storing serum, plasma, whole blood, and urine samples.

Quality Control

Running Quality Control

Steps for performing general quality control on the analyzer.

Maintenance

Cleaning the Internal Components of the Analyzer

Step-by-step guide for cleaning internal analyzer components.

Cleaning the Outside of the Analyzer and the Sample Drawer

Instructions for cleaning the exterior of the analyzer and sample drawer.