Operating instructions
Optical distance sensor
O1D102
80262529 / 00 03 / 2017
UK

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the IFM Electronic O1D102 and is the answer not in the manual?

IFM Electronic O1D102 Specifications

General IconGeneral
BrandIFM Electronic
ModelO1D102
CategoryAccessories
LanguageEnglish

Summary

Safety Instructions

Sensor Functions

Output Function Hysteresis

Explains how hysteresis maintains stable output switching based on measured values.

Output Function Window

Describes the window function for monitoring defined acceptable ranges for object detection.

Analogue Output Function

Explains the sensor's ability to output an analogue signal proportional to the distance.

Installation Guide

Installation Conditions

Specifies requirements for measuring range, unambiguity, and avoiding reflective objects.

Electrical Connection Procedures

IO-Link Master Operation

Explains how to operate the unit with IO-Link master port classes A and B.

Menu Structure and Navigation

Menu Structure Overview

Visual representation of the sensor's menu hierarchy and parameter flow.

Detailed Menu Parameter Explanations

Output 1 Configuration

Explains the configuration options for output 1, including switching functions.

Hysteresis Switch Point OUT1

Details setting the switch point for hysteresis function on output 1.

Window Switch Points OUT1

Explains setting near and far switch points for window function on output 1.

Output 2 Configuration

Covers configuration options for output 2, including switching functions and analogue signals.

Analogue Start Point (ASP)

Defines the measured value for the analogue output's start point (4 mA / 0 V).

Advanced Parameter Setting Details

Analogue End Point (AEP)

Defines the measured value for the analogue output's end point (20 mA / 10 V).

Teach Mode Setup

Explains how to use the teach mode for setting sampling rate and repeatability.

Parameter Setting Procedures

General Parameter Setting Guidelines

General instructions for parameter setting, emphasizing the importance of initial unit selection.

Setting Individual Parameter Values

Step-by-step guide on how to select and adjust individual parameter values.

Basic Configuration Settings

Hysteresis Function Operation

Window Function Operation

Output 2 Configuration and Analogue Scaling

Hysteresis Switch Point OUT2

Details setting the switch point for hysteresis function on output 2.

Window Switch Points OUT2

Explains setting near and far switch points for window function on output 2.

Analogue Output Scaling

Guides on scaling the analogue output by defining start and end points.

Initial Setup and Operation Checks

Troubleshooting: Fault Indication Guide