OPERATION MANUAL
IFF-701Ti
1-3-1
Page 8
Jul 1/00
1.8 POWER METER
Range: 0 to 100 W, 0 to 10 W
Accuracy: ±3% full scale ±5% of reading
Duty Cycle:
≤20 W: Continuous
>20 W to 40 W: 5 minutes on, 50% Duty Cycle
>40 W to 80 W: 1 minute on, 20% Duty Cycle
>80 W to 100 W: 0.5 minute on, 10% Duty Cycle
1.9 BATTERY LEVEL MONITOR
Range: 0 to 30 V
Accuracy: ±5% of reading
1.10 BEARING MONITOR
Range: ±0.5° (0° at meter center)
1.11 BATTERY
Type: 2.0 AH NiCad
Duration: ≈ 1.5 Hours Continuous