1.12 AC POWER
Input Range: 100 to 120 VAC, 60 Hz
220 to 240 VAC, 50 Hz
Power Consumption: 38 W Maximum
28 W Nominal at 115 VAC
22 W Nominal at 230 VAC
Fuse Requirements:
100 to 120 VAC: 1.0 A, 250 V, Type F
220 to 240 VAC: 0.5 A, 250 V, Type F
Mains Supply Voltage Fluctuations: ≤±10% of the nominal voltage
Transient Overvoltages: According to Installation Category II
1.13 ENVIRONMENTAL
Use: Pollution Degree 2
Altitude: 4000 meters (13,124 feet)
Temperature: 5° to 40°C (41°F to 104°F)
Relative Humidity: 80% for temperatures up to 31°C (88°F), decreasing
linearly to 50% at 40°C (104°F)

Table of Contents