3 – 18
MAINTENANCE
Change the Secondary Element
* Always replace the secondary filter element.
NEVER attempt to reuse it by cleaning.
* The secondary filter element should be
replaced at the time the primary element is
serviced for five time.
Replacement: When replaced the primary
element with the secondary element.
1. Remove the service cover
c
and the primary
element
d
from the air cleaner housing
e
.
2. Remove the secondary element
f
from the air
cleaner housing
e
. Cover the engine intake
opening.
3. Clean the inside of the air cleaner housing
e
and service cover
c
. Remove the covering from
the intake opening.
NOTE: Clean the seal tube in the cleaner housing.
Dust on the seal tube causes dust leak.
4. Install the new secondary element
f
.
5. Install the primary element
d
secure the service
cover
c
.
6. Reset the dust indicator
h
by pushing in the reset
button.
CAUTION
250HOURS
c
Service cover
e
Cleaner housing
f
Secondary element
g
Valve
d
Primary element
Install
Primary Element
Reset button
h
Indicator