CONTROLS
IC75 ENG 2-8
Engine key switch
Use this switch to start and stop the engine.
OFF (stop) position
The key may be inserted and pulled out. All currents
are cut off. Fuel injection stops and the engine stops
when the key switch is set to the OFF position.
ON (run) and GLOW (preheat) positions
The electrical system is turned on.
The temperature sensor senses the temperature and
the engine is preheated automatically for 1 to 15
seconds.
The glow lamp is on during preheating.
START position
Set the key to this position to start the engine.
Release the hand from the key immediately after the
engine starts.
The key returns to the ON position automatically.
Safety warning devices
Slope warning lamp
The warning lamp (1) of the slope warning device on the
ceiling goes on (red) and the alarm buzzer sounds for 5
seconds, if the machine is inclined forward by 9° or more
while moving down a slope.
Overrun warning lamp
The warning lamp (2) on the ceiling goes on and the
alarm buzzer keeps sounding, if the engine speed
exceeds 2300 min
-1
while moving down a slope.
ALARM POWER
O
ve
r
run
warning lamp
Sl
ope
warning lamp
Safety warning devices
Warning lamp positions
Posture that activates the safety warning devices