Installation
2020-02-26 57
4.3.3 Parallel Operation (Stacking)
If you have special configurations, especially at installations with several
monitors per work station or additional support of USB 2.0 transmission
paths, the number of connectable CPUs and consoles can be increased
by a parallel operation (stacking) of several Draco tera devices.
One Draco tera matrix is defined as the Master Matrix and its IP address
entered into the Master IP Address field (see Chapter 5.4.1, Page 83). All
other matrices are defined as Sub Matrices. Sub matrices must be
connected to the master matrix via network connector (RJ45) on the CPU
board. The Enable LAN Echo option has to be activated at the master
matrix (see Chapter 5.4.1, Page 83).
If a switching command is performed using the OSD, the synchronized
matrices will also switch automatically.
Switching of stacked devices might be delayed by several seconds.