Draco tera
94 2014-04-15
Field Selection Description
DEB
Activate debug messages in Trace
(default: NO)
Note:
The debug messages are exclusively for
matrix diagnostics. They only should be
activated after consultation with the
manufacturer. Otherwise an increased
traffic of data might limit the performance
of the CPU board.
INF
Activate information messages in Trace
(default: NO)
NOT
Activate notification messages in Trace
(default: YES)
WAR
Activate warning messages in Trace
(default: YES)
Trace
ERR
Activate error messages in Trace
(default: YES)
DEB
Activate debug messages in Syslog
(default: NO)
Note:
The debug messages are exclusively for
matrix diagnostics. They only should be
activated after consultation with the
manufacturer. Otherwise an increased
traffic of data might limit the performance
of the CPU board.
INF
Activate information messages in Syslog
(default: NO)
NOT
Activate notification messages in Syslog
(default: YES)
WAR
Activate warning messages in Syslog
(default: YES)
Syslog
ERR
Activate error messages in Syslog
(default: YES)
Activate the modified network parameters by restarting the matrix.
Consult your system administrator before modifying the network
parameters. Otherwise unexpected results and failures can occur in
combination with the network.