45
FAULT CAUSE TROUBLESHOOTING
E:18 or indicator for
water supply lights up.
The flow rate must be at
least 10 l/min when the wa-
ter supply is open.
Filter in the water sup-
ply is blocked.
1. Switch off the appliance.
2. Pull out the mains plug.
3. Turn off the water tap.
4. Unscrew the water connec-
tion.
5. Remove the filter from the
supply hose
6. Clean the filter.
7. Re-insert the filter in the sup-
ply hose.
8. Screw the water connection
back on.
9. Check the water connection
for leaks.
10. Restore the power supply.
11. Switch the appliance on.
E:22 lights up. Filters are soiled or
blocked.
● Clean the filters.
→"Cleaning filters", Page41
E:24 lights up. Water is
not drained.
Wastewater hose is
blocked or kinked.
1. Reposition the wastewater
hose without kinks.
2. Remove residues.
Siphon connection is
still sealed.
● Check the connection to the
siphon and open if neces-
sary.
Cover of the wastewa-
ter pump is loose.
● Secure the cover of the
Wastewater pump
→Page57 so it clicks into
position.