EasyManua.ls Logo

imacon Flextight Progression - Disposal; Technical Specifications

Default Icon
226 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Imacon Flextight Progression UserÕs Guide
Hardware ReferenceÑFlextight Progression
Disposal
40
English
Disposal
If you need to dispose of the scanner, it must be delivered to the local
waste plant.
Technical Specifications
Power Consumption
Max. 70W during operation
Power Requirements
100-240V AC, 1.3A, 50-60Hz
Earth connection necessary
Interface to Computer
SCSI-2 (ANSI X3.131)
Front Panel
Power on/off/cancel button
Drawer out/cancel button
Status indicator LED's
Noise Generation
£ 60 dB @ 1m when focusing
£ 60 dB @ 1m when scanning
Drum Force
< 1kg (2.2lbs)
Operating Environment
Temperature: 10°C-35°C (50°F-95°F)
Humidity: 20%-80%RH (no condensation).
Storage Environment
Temperature: 0°C-50°C (32°F-122°F)
Relative humidity: 20%-80%RH (no condensation)
Drum scanner Formats
Transparencies: from 35mm to 4x5 inches, £1mm thick
Flatbed Formats
¥ Electrostatic holder for one or more reßectives with total area up
to 314 x 460 mm (A3), £1mm thick
¥ Glass plates for multiple transparencies with total area up to
314 x 460 mm (A3), £10 mm thick
¥ Glass plates for one or more reßectives with total area up to
314 x 460 mm (A3), £10 mm thick
Lamp types
Drum: Osram FM 6w/860
Light table: Osram FM 8w/860
Flatbed reßective: Osram FM 11w/860
Flatbed transmission: Osram FM 11w/860

Table of Contents

Related product manuals