2. TECHNICAL DATA
POWER SUPPLY= N° 2 1.5V alkaline batteries, type LR6
NORMAL TEMPERATURE RANGE “T1” = 5÷30°C
REDUCED TEMPERATURE RANGE “T2” = 6°/14°/16°/18°C (winter mode)
38°/30°/28°/26°C (summer mode)
ROOM TEMPERATURE RANGE ON DISPLAY= 0/40°C (accuracy 0.1°C)
TEMPERATURE UPDATING= once a minute
ADJUSTABLE TEMPERATURE DIFFERENTIAL= 0.2K or 0.8K
SENSING ELEMENT = NTC 2%
DEGREE OF PROTECTION= IP 20
OUTPUT= switching relay
CONTACTS RATING= 5(0.5)A/250V~
SWITCH ACTION= 1BU
INSTALLATION LOCATION = normal environment
MAXIMUM STANDING TEMPERATURE= 50°C
STORAGE TEMPERATURE= 0÷60°C
4