VICTRIX 24 kW
Instant wall-hung boilers
condensation-type
VICTRIX 24 kW
VICTRIX 24 kW X
VICTRIX 24 kW X
Condensation-type wall-hung
boiler for central heating only
or with an external
storage tank

Other manuals for Immergas VICTRIX 24 kW X

Questions and Answers:

Immergas VICTRIX 24 kW X Specifications

General IconGeneral
BrandImmergas
ModelVICTRIX 24 kW X
CategoryBoiler
LanguageEnglish

Summary

VICTRIX 24 kW

VICTRIX 24 kW X

General Features

Detailed overview of the VICTRIX 24 kW X boiler's general characteristics and capabilities.

VICTRIX 24 kW Hydraulic Diagram

VICTRIX 24 kW X Hydraulic Diagram

Hydraulic Circuit Explanation

Detailed explanation of the VICTRIX 24 kW X boiler's hydraulic system and component flow.

Safety Devices and Checks (Combined Versions)

Safety Devices and Checks (Central Heating Versions)

Secondary Circuit (DHW)

DHW Operation

How the secondary circuit operates for domestic hot water requests, prioritizing DHW.

Air-Gas Circuit

Air-Gas Circuit Functioning

How the fan, valve, Venturi, and burner interact for combustion.

Air-Gas Adjustments

Adjusting Nominal and Minimum Heat Output

Procedure for adjusting the boiler's heat output and fan speed.

Air-Gas Ratio and Gas Valve Adjustments

Air-Gas Ratio Adjustment (Off-Set)

Fine-tuning the air-gas ratio based on CO₂ measurements.

Gas Valve DUNGS Calibration

Steps for calibrating the gas valve for CO₂ levels according to serial number.

VK 4115 Gas Valve

Gas Transformation and Calibration

How to adapt the gas valve for different gas types and calibrate CO₂.

Flue Circuit

Flue Circuit Functioning

How the fan, heat exchanger, and flue hood manage combustion gases.

Intake and Outlet Systems

Electric Circuit

230 V AC Circuit Overview

Diagram and explanation of the 230V AC electrical circuit of the boiler.

Safety Devices and Controls

Overview of safety devices and controls integrated into the electrical system.

Loads (Electrical Components)

Integrated P.C.B.

Description of the integrated P.C.B. controlling boiler functions.

Low Voltage Circuit Safety and Controls

Safety Devices and Controls (Low Voltage)

Overview of safety devices and controls operating on low voltage.

Main Selector Switch (S2)

Operation of the main selector switch for different boiler modes.

Loads (Control and Display)

Display Board (A4)

Display of functioning values, error codes, and status symbols.

Integrated P.C.B.

Operation

General operation of the integrated P.C.B. for boiler functions.

Central Heating Request

Sequence of operations when a central heating request is made.

Electric Circuit - DHW Mode

DHW Mode Operation

Sequence of operations for the boiler in domestic hot water mode.

DHW Requests and Special Conditions

DHW Request for Instant Boilers

How instant boilers respond to DHW withdrawal requests.

DHW Request for Storage Tank Boilers

How boilers with storage tanks handle DHW requests.

Anti-Freeze Request Operation

Boiler operation during central heating or DHW anti-freeze conditions.

Chimney Sweep Request

How to activate the chimney sweep function and its operation.

Inputs

Main Selector Switch Input (S2)

Activates boiler modes and allows reset/calibration.

Outputs

Adjustments

Safety Devices

Safety Thermostat Block

Blocks operation if water overheating safety thermostat opens.

Flue Safety Thermostat Block

Blocks operation if flue safety thermostat opens due to impurities.

Ignition Block

Boiler functioning is blocked if flame is not detected within 10 seconds.

Insufficient Circulation

Blocks burner if temperature increases rapidly due to low circulation.

Parasite Flame Block

Boiler functioning is blocked if ionization current is detected without gas valve open.

Fan Safety Speed

Blocks burner if fan speed is outside safe limits.

Functioning Anomaly Signals

VICTRIX 24 kW Functioning Sequence

VICTRIX 24 kW / 24 kW X Combustion Parameters

Related product manuals