STV75 ed 01/08 VICTRIX 75
VICTRIX 75 hydraulic circuit.
Legend:
1 - External funnel drain
2 - ISPESL certied 4 Bar safety valve
3 - Boiler draining valve
4 - Absolute pressure switch
5 - Flow manifold
6 - Gas valve
7 - Air fan
8 - Gas nozzle
9 - Air intake tube
10 - Ignition electrode
11 - Condensation module cover
12 - Condensation module
13 - Flue thermostat
14 - Flue hood
15 - Air sample point
16 - Flue sample point
17 - Automatic air vent valve
18 - System ow adjustment probe
19 - System return adjustment probe
20 - Overheat safety thermostat
21 - Burner
22 - Detection electrode
23 - Air/gas venturi manifold
24 - Positive Venturi signal (P1)
25 - Boiler pump
26 - Condensate siphon
M - System ow
G - Gas supply
SC - Condensate discharge
R - System return