RV CONTROL AND MONITORING SYSTEM
Patent # (D776,068)
Patent # (D762,644)
Patent # US 9,679,735
NCSP3
Installation and Operation Manual

Questions and Answers

  • R
    richardmcdonaldAug 8, 2025
    How to troubleshoot IN-COMMAND Measuring Instruments Display Commander (DC) when it will not turn ON?
    • C
      cmcmahonAug 8, 2025
      If the IN-COMMAND Measuring Instruments Display Commander (DC) won't turn on or the front panel isn't working, try these steps: * First, check for +12VDC on the Positive (+) input at the back of the DC. * Next, verify there is Ground on the Negative (-) input, also on the back of the DC. * Then, inspect the fuse in the Distribution Panel. * Finally, attempt to cycle the power using the power button.
  • S
    Sandra CunninghamAug 12, 2025
    What to do if there is no power to the IN-COMMAND NCSP3 Body Control Module (BCM)?
    • N
      nicole96Aug 12, 2025
      If there is no power to the IN-COMMAND Measuring Instruments Body Control Module (BCM), verify the following: * Check for +12VDC on pin 90. * Check for Ground on pin 86. * Check the fuse in the Distribution Panel.
  • R
    Richard HillAug 16, 2025
    Why is my IN-COMMAND NCSP3 DC screen flashing on and off after installation?
    • D
      David RandolphAug 16, 2025
      If the IN-COMMAND Measuring Instruments DC screen is flashing after installation, follow these steps: 1. Disconnect the power wires from the back of the DC. 2. Turn off all power to both the DC and BCM. 3. Reconnect the power wires to the DC. 4. Restore power to the DC and BCM. 5. Press the Reset button on the BCM.
  • K
    Karen GreenAug 21, 2025
    What to check if awnings do not move using IN-COMMAND NCSP3?
    • G
      George BakerAug 21, 2025
      If the awnings aren't moving with your IN-COMMAND Measuring Instruments, check for +12VDC on Pin 88 and make sure the relay activates.
  • A
    Alex VillanuevaAug 26, 2025
    What to check if slide rooms do not move using IN-COMMAND NCSP3?
    • S
      Stephanie BrennanAug 26, 2025
      If the slide rooms are not moving with your IN-COMMAND Measuring Instruments, check for +12VDC on Pin 89. Ensure the relay activates.
  • T
    Tammy LewisAug 30, 2025
    What does it mean if IN-COMMAND NCSP3 Measuring Instruments DC shows 0V and no functions activate?
    • T
      Terry GuerraAug 30, 2025
      If the IN-COMMAND Measuring Instruments DC shows 0V and no functions are activating, check the RV-C cable for shorts and inspect the connection for loose pins.
  • J
    James AguilarSep 3, 2025
    What to do if relay not activating in IN-COMMAND Measuring Instruments?
    • S
      Stephanie BarnesSep 3, 2025
      If a relay is not activating in your IN-COMMAND Measuring Instruments system, replace it with a relay from an unused circuit. Refer to the label on the BCM cover for relay identification.