Board Users Manual 13 of 27 Revision V1.1
2021-09-21
User Manual AURIX™ TCxx4 lite Kit
AURIX™ TCxx4 lite Kit
3 Configuration
3.1 Bootmode
Table 6 User Startup Modes
1)2)3)
Start-up mode is selected by Boot Mode Index
Internal Start from Flash
Alternate Boot Mode, Generic Bootstrap Loader on fail
(P14.0/P14.1)
Generic Bootstrap Loader (P14.0/P14.1)
1) The shadowed line indicates the default setting.
2) ‘A’ means assembled, ‘NA’ means not assembled, ’x’ represents the don’t care state.
Please see also Table 8.
3.2 Config Signals
Table 7 Config Signals
Only with TC234, resistor R30 (4.7 kΩ/0603 imp) pulls
signal against GND (DCDC) and is assembled initially
if board is using TC234.
HWCFG1 (EVR33ON / EVR33OFF)
Only with TC3X4, resistor R31 (4.7 kΩ/0603 imp) pulls
signal against GND (EVR33OFF) and is assembled
initially.
HWCFG2 (EVRCON / EVRCOFF for TC3X4)
HWCFG2 (EVR13ON / EVR13OFF for TC2X4)
Resistor R52 (4.7 kΩ/0603 imp) must be assembled if
R59 is assembled (GPIOs are set to tri-state).
HWCFG3 (see boot configuration Table 6)
HWCFG4 (see boot configuration Table 6)
HWCFG5 (see boot configuration Table 6)
HWCFG6 (GPIOs pull-up / tri-state)
Only with TC3X4, resistor R59 (4.7 kΩ/0603 imp) pulls
signal against GND (GPIOs in tri-state after reset) and
and is not assembled initially.