IDS404 INSTALLER MANUAL NO. 700-277-02A ISSUED SEPT 2004 VER 1.02 45
IDS404 INSTALLER MANUAL
Disable swinger shutdown by entering [0] in this location.
161NOITACOLesnopseRpooLenoZ
eulaV
noitcA
0
tluafeD
emitesnopseR sm001-
1emitesnopseRsm21-
The zone loop response is the period of time for which the zone must
be violated before a violation is registered. A value of [0] provides a loop
response time of 100ms.
261NOITACOL)0=tluafeD(tnuoCpirTenoZ
This feature is to prevent false alarms while the panel is armed. If the
panel is armed and a follower zone is violated the number of times
programmed into this location within the time period programmed into
location 163, then an alarm condition will be registered. Program a
value from [0] to [15]; a [0] will disable the location. Please note that
this only applies to follower zones and instant zones remain instant.
361NOITACOL)0=tluafeD(yaleDemiTtnuoCpirTenoZ
This time delay period applies to location 162. If the panel is armed
and the number of violations programmed into location 162 occurs
within this time delay, an alarm condition will register. Program a value
from [0] to [15]. Multiply the value of the entry by 10 seconds to
calculate the delay time.
461NOITACOL1yalpsiDelbuorTelbammargorP
eulaV
foyalpsiD
repmaTneriS
foyalpsiD
repmaTdapyeK
0
##
1
$
#
2
#
$
3
tluafeD
$ $
$
delbanE
#
delbasiD
This location determines whether siren tamper or keypad tamper are