17
6.4.2 Alarm High / Low Temperature Limit
Settings (AH,AL)
When measured temperature ≥AH (high
temperature limit alarm), hen it will turn
off heating or cooling output, AH flashes
alternately with the current temperature,
meantime buzzer will“bi-bi-Biii”alarm, until
the temperature <AH, buzzer off and return
to normal display and control. Or press
any button to turn the buzzer alarm off
only . When measured temperature ≤ AL
(low temperature alarm), then it will turn
off heating or cooling output, AL flashes
alternately with the current temperature,
meantime buzzer will “bi-bi-Biii”alarm, until
the temperature >AL, buzzer off and return
to normal display and control. Or press
any button to turn the buzzer alarm off only.
High and low temperature limit alarm will
be pushed to mobile APP and remind the
customer that the product is in alarm state.
6.4.3 Compressor Delay Time(PT)
In the cooling mode, when the power