18
is turned on for the first time, PV(mea-
sured temperature value) ≥ TS(Tempera-
ture setting value) + CD(Cooling difference
value), it will not start cooling immediately,
but waiting for a delay time(PT). When two
adjacent of cooling starting intervals are
greater than the delay time, it will immedi-
ately start cooling; When two adjacent of
cooling starting intervals are less than the
delay time, it needs to operate the remain-
ing delay time to start the cooling.
Delay time will start counting from the
cooling output off.
6.4.4 Temperature Calibration(CA)
When the measured temperature deviates
from the standard temperature, the
temperature calibration function can be
used to make the measured value of the
instrument consistent with the standard
value. The calibrated temperature = the
measured temperature + the calibration
value.