INOV8 Model F240 – Edited September 2008
41
2. Press UP or DOWN to increase or decrease the value of SP2 and press SET to
confirm the new value and exit. The range of temperature for this setting is 100
o
F to
140
o
F.
Note: At least 20
o
F span must be between the OUT1 and OUT2 settings for this to
function properly. Also be aware that when the preheater switch (see item #24 on
the burner diagram for location) is in the OFF or “0” position, the lights on the
temperature control will be off.
Message Display
Under normal operation, the temperature of the probe will be displayed. Call INOV8 if
any of the following messages appear:
• Err Memory reading error
• AH1 Maximum temperature alarm
• AL1 Minimum temperature alarm
• ooo Open probe
• --- Shorted probe
REMOVING EXCESS OIL FROM COMBUSTION CHAMBER
While this should never happen with the Fireye combustion control that is specifically
designed to prevent excess oil, follow this procedure if necessary. If unburned oil
accumulates, DO NOT attempt to fire the heater and burn off the oil. Perform steps
on page 27 for shutting down power and removing the burner for cleaning the
combustion chamber. Scoop out any excess oil. It can be returned to the tank if properly
filtered. Put in “Oil Dry” to absorb any wet oil, and scrape out and discard. If oil is
present in the heat exchanger tubes, perform the same cleaning routine in them.
PROCEDURE FOR PARTS REPLACEMENT
If it is determined that part of the furnace is faulty, a replacement part will be sent via
UPS regular delivery. If overnight delivery is desired, the service will be billed to you.
The billing will depend upon the warranty provisions. These additional conditions apply
to the replacement policy:
1. For the first twelve months of owning the furnace, all shipping of warranted parts
from the factory is paid for by INOV8. The customer is responsible for returning the
faulty part to INOV8 or the INOV8 dealer. After the first year the owner shall pay the
costs of shipping.
2. During the first year an invoice will be issued for the replacement part. When the
faulty part is received at the factory, full credit will be issued.
3. INOV8 reserves the right to send a representative for an on-site inspection.
4. INOV8 is not responsible for any labor cost for the servicing, removal or replacement
of parts.
5. Repaired or exchanged equipment will carry the unexpired portion of the original
equipment warranty or six months, whichever is greater.
6. If inspection by INOV8 discloses a defect not covered by this warranty, the equip-
ment will be returned as is, repaired, or replaced at the discretion of the owner. If
repaired in the factory, INOV8's regular labor charges will apply.
7. This provision expires one (1) calendar year from the date of delivery.