OnTime Clock
Installation and User Guide
Firmware Version 2
All claims based on information publicly available at time of printing. All other product or service names mentioned
in this document may be trademarks of the companies with which they are associated.
© 2017 Inova Solutions | All rights reserved | page 27
5. Enter the user name: iclock.
6. When the clock’s password prompt appears (iclock password: ), enter the
clock’s password (the default is timely).
7. The clock’s telnet prompt appears: iclock-### />)
8. You are now ready to set configuration using the telnet commands.
For help with a specific telnet command, at the prompt, type help followed by the
desired command. For example, to see help for the display option, type help display.
7.2. Configuring an IP Address
There are two options for configuring an IP Address on each OnTime Clock:
DHCP [Factory Default]
Assigned Static IPv4 Address
7.2.1. DHCP
The factory default is DHCP. Refer to Section 6 for more information about DHCP.
Refer to Appendix A: Clock Configuration for help changing from a Static IP Address to
DHCP by using the ipconfig –d command.
7.2.2. Assigned Static IPv4 Address
Note: Your IT staff must authorize and provide a static IPv4 address to prevent
operational problems which might occur if that address is applied to another device on
the network.
To enter a fixed IPv4 address into your clock’s firmware, start a telnet session with the
clock and the use the following command option:
ipconfig -a xxx.xxx.xxx.xxx -m yyy.yyy.yyy.yyy -g zzz.zzz.zzz.zzz
where:
xxx.xxx.xxx.xxx is the IPv4 address
yyy.yyy.yyy.yyy is the subnet mask
zzz.zzz.zzz.zzz is the gateway address
All fields must be provided.
You may also have to specify a primary DNS server; if possible, you may also wish to
specify a secondary DNS server. In order to sync to an internet time server (see below)
you will need to specify at least one DNS server by IP Address.
To enter the primary and secondary DNS servers while also configuring a static IP
Address, start a telnet session with the clock and use the following command option: