- 153 -
F9-21
Frequency upon
fault
Display the most recent failure of the
frequency
F9-22 Current upon fault
Display the current upon fault for the most
recent one time.
F9-23
Bus voltage upon
fault
Display the bus voltage upon fault for the
most recent one time.
F9-24
Input terminal
status upon fault
This value is a decimal number.Display the
status of all the digital input terminal upon
fault for the most recent one time,with
sequence of:
BIT
4
BIT
3
BIT
2
BIT
1
BIT
0
DI5………………………………DI1
It will be displayed in decimal number
converted from each digit status.
When the input terminal is ON, the
corresponding value is 1. When the input
terminal is OFF, the value is 0.
It can know the details regarding digital
output signal via this value.
F9-25
Output terminal
upon fault
This value is a decimal number.Display the
status of all the digital input terminal upon
fault for the most recent one time,with
sequence of:
BIT
2
BIT
1
BIT
0
REL3 REL2 REL1
It will be displayed in decimal number
converted from each digit status.
When the input terminal is ON, the
corresponding value is 1. When the input
terminal is OFF, the value is 0.
It can know the details regarding digital
output signal via this value.

Table of Contents

Other manuals for Inovance IS300T030-C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300T030-C and is the answer not in the manual?

Inovance IS300T030-C Specifications

General IconGeneral
BrandInovance
ModelIS300T030-C
CategoryServo Drives
LanguageEnglish

Related product manuals