Foreword
IS300 series servo driver is a servo driver which is specially desiged for Drive
permanent magnet synchronous servo motor (PMSM). IS300 series servo
driver has a wide capacity rangethe rated current is 5A to 300A.It’s able to
provide not only servo pump control, but also the general functional
requirements.And it is a high-power servo driver which is value-for-money in
the present market.
This manual is a guide to the operations of IS300 series servo driver.
This manual provides the user with related precautions and instructions for the
prototyping, installation, parameter setup, and on-site commissioning, and
routine repair and maintenance of servo driver. In order to use this series of
driver correctly, please read this manual carefully prior to operation and keep it
properly for future using. The supporting equipment customers shall distribute
this manual together with the equipment to the final users.
Unpacking and inspection:
Please confirm carefully when unpacking the box:
1) If the model and driver rated values on the nameplate are the same as
your order. The box contains the equipment, certificate of conformity,
user manual and warranty card.
2) If the product is damaged during the transportation. If there is any
omission or damage, please contact our company or the supplier
immediately.
First time use:
The users who use this product for the first time shall read this manual
carefully. For any doubt on certain functions and performances, please contact
the technical support personnel of our company for help so as to use this
product properly.
With commitment to the constant improvement of the servo driver, our
company may change the information provided without additional notice.

Table of Contents

Other manuals for Inovance IS300T300-C

Question and Answer IconNeed help?

Do you have a question about the Inovance IS300T300-C and is the answer not in the manual?

Inovance IS300T300-C Specifications

General IconGeneral
Control ModeTorque, Speed, Position
Communication InterfaceRS-485, CANopen
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheating
Operating Temperature0°C to 45°C
Storage Temperature-20°C to 65°C
Humidity5% to 95% RH, non-condensing
Vibration Resistance5.9 m/s² (10-55Hz)
Input Voltage3-phase 220VAC (-15% to +10%)

Summary

Chapter 1 Safety and Precautions

Chapter 2 Product Information

Technical Specifications Overview

Detailed technical specifications of the IS300 servo driver.

Routine Repair and Maintenance

Guidelines for routine repair and maintenance of the servo driver.

IS300 Series Models and Data

Table listing IS300 series models and their technical data.

Mounting Hole Dimensions

Table detailing physical dimensions and mounting hole sizes.

Chapter 3 Mechanical and Electric Installation

Electrical Installation Guidance

Guidance on external electrical parts and wiring.

Control Terminals and Connections

Overview of control circuit terminals and their layout.

Main Circuit Terminals and Wiring Precautions

Description of main circuit terminals and safety wiring precautions.

Chapter 4 Operation and Display

Shortcut Menu Operation

How to use and manage the shortcut menu for quick access.

Automatic Motor Parameter Tuning

Procedures for automatic motor parameter tuning in vector control mode.

Keyboard Button Functions

Table detailing keyboard buttons and their functions.

Status Parameter Viewing

How to view running and stop status parameters using function codes.

Function Code Viewing and Modification

Explanation of the three-level menu structure for parameter setting.

Password Setup Procedure

How to set up and cancel the user password protection function.

Chapter 5 Function Parameter Table

Chapter 6 Parameter Description

Group F5 Output Terminal Parameters

Parameters for configuring relay and analog output terminals.

Group F8 Auxiliary Function Parameters

Parameters for jog running frequency and speed-up/down times.

Group F3 V/F Control Parameters

Parameters for V/F curve setup and torque boost.

Group F6 Start/Stop Control Parameters

Parameters for startup mode and rotation speed tracking.

Group F9 Fault and Protection Parameters

Parameters for motor overload protection selection and gain.

Group F7 Keyboard and Display Parameters

Parameters for LCD language selection and MF.K key function.

Chapter 7 Servo Pump Commissioning Steps and Prototyping of servo pump optional parts

Servo Pump Commissioning Steps

Detailed steps for motor commissioning, including parameter tuning.

Servo Driver Prototyping

Capacity selection criteria for servo drivers based on motor parameters.

Chapter 9 Failure Diagnosis and Solution

Appendix 1: Common Parameters Table

Group U0 Driver Parameter Viewing

Table of parameters for viewing driver status and settings.

Group F2 Vector Control Parameters

Parameters specific to vector control mode, including speed loop gains.

Group A0 Weak Magnetism/SVC Control

Parameters related to weak magnetism and SVC control.

Group F0 Basic Function Parameters

Parameters for basic functions like control mode and command source.

Group F4 Input Terminal Parameters

Parameters for configuring digital input terminals.

Group F1 Motor Parameters

Parameters for defining motor type, power, voltage, and current.

Group FP User Password Parameters

Parameters for setting user password protection.