Chapter 7 Function Code Table IS620P User Manual
- 164 -
Function
Code
Parameter Name Setting Range Unit Default
Effective
Time
Property
Control
Mode
H02 24
Resistor heat
dissipation
coefcient
10–100 % 30 Immediate At stop PST
H02 25
Regen resistor
type
0: Built-in
1: External, natural
cooling
2: External, forced
air cooling
3: No resistor,
using only
capacitor
- 0 Immediate At stop PST
H02 26
Power of external
regen resistor
1–65535 W - Immediate At stop PST
H02 27
Resistance of
external regen
resistor
1–1000 Ω - Immediate At stop PST
H02 30 User password 0–65535 - 0
Power-on
again
At stop PST
H02 31
Parameter
initialization
0: No operation
1: Restore default
setting (except
groups H0 and H1)
2: Clear fault
records
- 0 Immediate At stop PST
H02 32
Default keypad
display
00–99 - 50 Immediate
During
running
-
H02 33
EtherCAT
software version
- - - -
At
display
-
H02 34
CAN software
version
- - - -
At
display
-

Table of Contents

Other manuals for Inovance IS620PS1R6I

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance IS620PS1R6I and is the answer not in the manual?

Inovance IS620PS1R6I Specifications

General IconGeneral
BrandInovance
ModelIS620PS1R6I
CategoryServo Drives
LanguageEnglish

Related product manuals