5 Parameter Table
- 45 -
Para. No. Para. Name Setting Range Default Comms. Address
FC-17 Simple PLC retentive selection
00 to 11
0: Not retentive
1: Retentive
Retentive selection at stop
0: Not retentive
1: Retentive
Retentive selection at
power down
00 0xFC11/0x0C11
FC-18
Running time of simple PLC
reference 0
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC12/0x0C12
FC-19
Acceleration/deceleration time of
simple PLC reference 0
0 to 1 0 0xFC13/0x0C13
FC-20
Running time of simple PLC
reference1
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC14/0x0C14
FC-21
Acceleration/deceleration time of
simple PLC reference 1
0 to 1 0 0xFC15/0x0C15
FC-22
Running time of simple PLC
reference 2
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC16/0x0C16
FC-23
Acceleration/deceleration time of
simple PLC reference 2
0 to 1 0 0xFC17/0x0C17
FC-24
Running time of simple PLC
reference 3
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC18/0x0C18
FC-25
Acceleration/deceleration time of
simple PLC reference 3
0 to 1 0 0xFC19/0x0C19
FC-26
Running time of simple PLC
reference 4
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC1A/0x0C1A
FC-27
Acceleration/deceleration time of
simple PLC reference 4
0 to 1 0 0xFC1B/0x0C1B
FC-28
Running time of simple PLC
reference 5
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC1C/0x0C1C
FC-29
Acceleration/deceleration time of
simple PLC reference 5
0 to1 0 0xFC1D/0x0C1D
FC-30
Running time of simple PLC
reference 6
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC1E/0x0C1E
FC-31
Acceleration/deceleration time of
simple PLC reference 6
0 to 1 0 0xFC1F/0x0C1F
FC-32
Running time of simple PLC
reference 7
0.0s (h) to 6500.0s (h) 0.0s (h) 0xFC20/0x0C20
FC-33
Acceleration/deceleration time of
simple PLC reference 7
0 to 1 0 0xFC21/0x0C21
FC-50 Time unit of simple PLC running
0: s
1: h
0 0xFC32/0x0C32
FC-51 Reference 0 source
0: Set by FC-00
1: AI
2: External operating panel potentiometer
4: PULSE reference
5: PID
6: Set by F0-08 and modied via UP/DOWN
0 0xFC33/0x0C33