6. Description of Parameters
- 122 -
6
Function Code Parameter Name Setting Range Default
FC-41
Acceleration/deceleration time of
simple PLC reference 11
0 to 3 0
FC-42
Running time of simple PLC
reference 12
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-43
Acceleration/deceleration time of
simple PLC reference 12
0 to 3 0
FC-44
Running time of simple PLC
reference 13
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-45
Acceleration/deceleration time of
simple PLC reference 13
0 to 3 0
FC-46
Running time of simple PLC
reference 14
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-47
Acceleration/deceleration time of
simple PLC reference 14
0 to 3 0
FC-48
Running time of simple PLC
reference 15
0.0s (h) to 6553.5s (h) 0.0s (h)
FC-49
Acceleration/deceleration time of
simple PLC reference 15
0 to 3 0
FC-16 determines the simple PLC running mode.
Function Code Parameter Name Setting Range Default
FC-16
Simple PLC
running mode
0: Stop after running one cycle
.HHS¿QDOYDOXHVDIWHUUXQQLQJRQHF\FOH
2: Repeat after running one cycle
0
Ɣ
FC-16 = 0: Stop after running one cycle
The AC drive stops after running one cycle, and will not start until it receives a new
RUN command.
Ɣ
)& .HHS¿QDOYDOXHVDIWHUUXQQLQJRQHF\FOH
7KH$&GULYHNHHSV¿QDOUXQQLQJIUHTXHQF\DQGGLUHFWLRQDIWHUUXQQLQJRQHF\FOH
Ɣ FC-16 = 2: Repeat after running one cycle
The AC drive automatically starts another cycle after running one cycle, and will not
stop until receiving stop command.