6. Description of Parameters
- 152 -
6
6.5.5 Improving Field Weakening Area Performance
Function Code Parameter Name Setting Range Default
A5-05
0D[RXWSXWYROWDJHFRHI¿FLHQW 100% to 110% 105%
This parameter indicates boost capacity of maximum voltage of the AC drive. Increasing A5-05
ZLOOLPSURYHPD[ORDGLQJFDSDFLW\LQPRWRU¿HOGZHDNHQLQJDUHD%HDZDUHWKDWWKLVPD\OHDGWR
an increase in motor current ripple and an increase in motor heating.
Decreasing it will reduce motor current ripple and motor heating. Be aware that this will lower
PD[ORDGLQJFDSDFLW\LQPRWRU¿HOGZHDNHQLQJDUHD$GMXVWPHQWRIWKLVSDUDPHWHULVQRWUHTXLUHG
normally.
6.5.6 Auxiliary Control
Function Code Parameter Name Setting Range Default
A5-00
DPWM switchover frequency upper limit 0.00 to 15.00 Hz 12.00 Hz
Increasing this parameter to the max. frequency will reduce motor audible noise.
Function Code Parameter Name Setting Range Default
A5-01
PWM modulation pattern 0: Asynchronous modulation
1: Synchronous modulation
0
When the output current oscillates or large current harmonics occur, set A5-01 = 1.
Function Code Parameter Name Setting Range Default
A5-03
Random PWM depth 0: Random PWM invalid
1 to 10
0
This parameter helps to lower motor audible noise and reduce electromagnetic interference.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD290T45G/55P and is the answer not in the manual?

Inovance MD290T45G/55P Specifications

General IconGeneral
BrandInovance
ModelMD290T45G/55P
CategoryDC Drives
LanguageEnglish

Related product manuals