8. Peripherals and Options
- 250 -
8
Ɣ
DIP switch setting
Table 8-11 Descriptions of DIP switch setting
Baud Rate 'H¿QLWLRQ Address setting 'H¿QLWLRQ DIP Switch
1 2 345678
0 0 125Kbps000000Reserved
ON
12 3
41
ON
ON
12 34
S2 S3
Baud
rate setting
CANopen
address setting
1 2 3 4 5 6 7 8
0000011
0 1 250Kbps0000102
0000113
1 0 500Kbps ...
11110161
1 1 1Mbps 11111062
11111163
Ɣ
Indicators
Table 8-12 Descriptions of indicators
Indicator State Description
PWR (in red) ON Power-on is normal.
OFF Power-on is abnormal. Check whether the
installation is proper.
ERR (in red) ON The communication of the AC drive times out.
Flashing quickly The CANopen address is set incorrectly.
Flashing twice The CANopen messages emergently.
RUN (in green) ON The CANopen enters the "Operational" state.
Flashing The CANopen enters the "Pre-Operational" state.
OFF The CANopen enters the "Stopped" state.
Note
CANopen
has the same bus topology and wiring method as CANlink
does.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inovance MD290T45G/55P and is the answer not in the manual?

Inovance MD290T45G/55P Specifications

General IconGeneral
BrandInovance
ModelMD290T45G/55P
CategoryDC Drives
LanguageEnglish

Related product manuals