2. Mechanical Installation
- 37 -
2
$VVKRZQLQWKHIROORZLQJ¿JXUHDQLQVXODWLRQEDUULHULVUHTXLUHGWRSUHYHQWKRWDLUFLUFXODWLQJ
inside the cabinet.
Figure 2-13 Insulation barrier in the cabinet
Cabinet air
outlet cover
Isolation
barrier
MD290
Ƶ
Precautions
Nine-folding AL cabinet (PS cabinet) is recommended for installation of the drive.
%HIRUHLQVWDOOLQJWKH$&GULYHFKHFNZKHWKHU¿[LQJEHDPVZLWK¿[LQJKROHVDUHPRXQWHG
to the cabinet back correctly. Then prepare bottom mounting bracket and guide rail.
5HVHUYHVXI¿FLHQWVSDFHDWWKHERWWRPRIWKHFDELQHWIRUVLGHHQWU\FRSSHUEDUMRLQWDQG
operation.
You can push the AC drive into the cabinet or pull it out of the cabinet after moving the
drive onto the guide rail. Make sure to align the castors to the guide rail and arrange two
persons for drive push-in and pull-out to ensure safety.
CAUTION
Ɣ
Refer to Figure 2-3 for mounting clearance requirements. Ensure
WKHUHLVVXI¿FLHQWVSDFHDOORZIRUHI¿FLHQWKHDWGLVVLSDWLRQRIWKH
drive and the other devices in the cabinet.
Ɣ
Arrange two persons for drive push-in and pull-out, as shown in
Figure 2-13 and Figure 2-14.
Ɣ
Refer to Figure 2-11 for cabinet layout before mounting the drive in
cabinet. Wind screen must be installed at the top of the cabinet to
DYRLGFLUFXODWLRQRI0'YHQWLODWLRQDLUÀRZ,QDGGLWLRQHQVXUH
there are air inlet openings at the bottom of the cabinet.
Ɣ
For the bottom mounting bracket (delivered together with the
product), see section
8
.