Function Code Table
MD380 User Manual
- 82 -
Function
Code
Parameter Name
Setting Range
Default Property
F0-12 Frequency upper limit
Frequency lower limit (F0-14) to
maximum frequency (F0-10)
50.00 Hz ☆
F0-13 Frequency upper limit offset
0.00 Hz to maximum frequency
(F0-10)
0.00 Hz ☆
F0-14 Frequency lower limit
0.00 Hz to frequency upper limit
(F0-12)
0.00 Hz ☆
F0-15 Carrier frequency
0.5–16.0 kHz
Model
dependent
☆
F0-16
Carrier frequency
adjustment with temperature
0: No
1: Yes
1 ☆
F0-17 Acceleration time 1
0.00–650.00s (F0-19 = 2)
0.0–6500.0s (F0-19 = 1)
0–65000s (F0-19 = 0)
Model
dependent
☆
F0-18 Deceleration time 1
0.00–650.00s (F0-19 = 2)
0.0–6500.0s (F0-19 = 1)
0–65000s (F0-19 = 0)
Model
dependent
☆
F0-19
Acceleration/Deceleration
time unit
0:1s
1: 0.1s
2: 0.01s
1 ★
F0-21
Frequency offset of auxiliary
frequency source for X and
Y operation
0.00 Hz to maximum frequency
(F0-10)
0.00 Hz ☆
F0-22
Frequency reference
resolution
1: 0.1 Hz
2: 0.01 Hz
2 ★
F0-23
Retentive of digital setting
frequency upon power
failure
0: Not retentive
1: Retentive
2 ☆
F0-24
Motor parameter group
selection
0: Motor parameter group 1
1: Motor parameter group 2
2: Motor parameter group 3
3: Motor parameter group 4
0 ★
F0-25
Acceleration/Deceleration
time base frequency
0: Maximum frequency (F0-10)
1: Set frequency
2: 100 Hz
0 ★
F0-26
Base frequency for UP/
DOWN modication during
running
0: Running frequency
1: Set frequency
0 ★