3. Electrical Installation
- 33 -
3
Figure 3-2 Terminal dimensions of MD500T30GB/37GB-INT
16.5
20.2
18
20.
2
20.2 20.2
161.6
M
6 combination screw
R S T U V W
POWER MOTOR
BR
(+) (-)
Table 3-3 Recommended cable dimensions and tightening torque of MD500T30GB/MD500T37GB-
INT
AC Drive Model Rated
Input
Current
(A)
Power
Input/Output
Cable
Crimp
Terminal
Model
Ground
Cable
Crimp
Terminal
Model
Tightening
Torque
(N·m)
Screw
Spec.
MD500T30GB-INT 57 3 x 16 mm
2
3 x 4 AWG
14-L6 16 mm
2
8 AWG
8-6 4.0 M6
MD500T37GB-INT 69 3 x 16 mm
2
3 x 3 AWG
14-L6 16 mm
2
6 AWG
14-L6 4.0 M6
Figure 3-3 Terminal dimensions of MD500T45GB/55GB-INT
R S
POWER
T
BR
(+) (-)
V
U
W
MOTOR
248
11
M8 flat washer
+ spring washer
+ nut
26.8
24.8
111
31
M8
combination
screw
Table 3-4 Recommended cable dimensions and tightening torque of MD500T45GB/MD500T55GB-
INT
AC Drive Model Rated
Input
Current
(A)
Power
Input/Output
Cable
Crimp
Terminal
Model
Ground
Cable
Crimp
Terminal
Model
Tightening
Torque
(N·m)
Screw
Spec.
MD500T45GB-INT 89 3 x 25 mm
2
3 x 2 AWG
22-8 25 mm
2
6 AWG
14-8 10.5 M8
MD500T55GB-INT 106 3 x 50 mm
2
3 x 1/0 AWG
60-8 25 mm
2
6 AWG
14-8 10.5 M8