User Guide
MD500 AC Drive
A03
Suzhou lnovance Technology Co., Ltd.
Address: No.16, Youxiang Road, Yuexi Town,
Wuzhong District, Suzhou 215104, P.R.China
http: //www.inovance.cn
MD500 AC Drive High Performance Open and Closed Loop User Guide
Data Code: 19010374
High Performance
Open and Closed Loop

Table of Contents

Questions and Answers

  • J
    Jason AliSep 23, 2025
    What to do if Inovance Controller shows encoder fault?
    • R
      Robert HintonSep 23, 2025
      If your Inovance Controller displays an encoder fault, verify that the encoder type is set correctly. Also, check the PG card power supply and phase sequence for incorrect wiring. If the issue persists, the encoder or PG card might be damaged, requiring replacement.
  • E
    Erin CainAug 23, 2025
    What to do if Inovance MD500 detects overload or overcurrent during motor running?
    • C
      Casey MaxwellAug 25, 2025
      If your Inovance Controller is showing an overload or overcurrent during motor running, set the motor parameters F1-01 to F1-05 according to the motor nameplate. Also, select a proper motor auto-tuning mode by setting F1-37 and perform motor auto-tuning. If possible, select dynamic auto-tuning.
  • J
    Julie NormanAug 25, 2025
    What causes IGBT overheat in Inovance Controller and how to fix it?
    • G
      Gregory SandovalAug 26, 2025
      IGBT overheat in your Inovance Controller can be caused by several factors. The ambient temperature may be too high, so lower it. Other potential solutions include cleaning the ventilation, replacing the cooling fan if it's damaged, replacing the damaged thermally sensitive resistor, or as a last resort, replacing the AC Drive IGBT.
  • B
    Brian JonesAug 27, 2025
    What to do if Inovance MD500 Controller shows motor overload?
    • E
      Ethan NunezAug 27, 2025
      If the Inovance Controller indicates a motor overload, it might be because the load is too heavy, or the motor has a locked rotor. Try reducing the load or inspecting the motor and mechanical components. If the issue persists, consider using a drive with a larger power class.
  • J
    Joshua OconnorAug 27, 2025
    What to do if Inovance MD500 Controller detects overload or overcurrent during motor start?
    • K
      Karen JamesAug 27, 2025
      If your Inovance Controller detects an overload or overcurrent fault during motor start, set F1-27, F1-28 and F1-30 correctly.
  • J
    John KirbySep 17, 2025
    How to reduce motor noise with Inovance MD500?
    • C
      Christine Patterson DDSSep 17, 2025
      To reduce loud motor noise with your Inovance Controller, gradually increase the setting of F0-15 (carrier frequency) by 1.0 kHz. Keep in mind that increasing the carrier frequency will result in an increase in the leakage current of the motor.
  • C
    Carol HernandezSep 14, 2025
    How to fix overcurrent during start with Inovance MD500 Controller?
    • P
      Patricia PatelSep 14, 2025
      To resolve overcurrent during start with your Inovance Controller, gradually decrease the setting of F3-01 (torque boost) by 0.5%.
  • C
    Christopher KimSep 15, 2025
    How to improve speed accuracy with Inovance MD500 Controller?
    • S
      Sharon EllisSep 16, 2025
      To improve speed accuracy on your Inovance Controller, if the speed error when the motor runs with load is large, increase the setting of F2-06 (vector control slip compensation gain) by 10% gradually.
  • W
    whiteamandaSep 6, 2025
    How to improve torque or speed response for Inovance MD500 at speeds above 5 Hz?
    • R
      Robert EvansSep 6, 2025
      To improve torque or speed response and address motor oscillation at speeds above 5 Hz on your Inovance Controller: if motor torque and speed response are too slow, increase the setting of F2-03 (speed loop proportional gain) by 10 gradually or decrease the setting of F2-04 (speed loop integral time) by 0.05 gradually. If motor oscillation occurs, decrease F2-03 and increase F2-04.
  • T
    Travis SmithSep 3, 2025
    What to do if Inovance MD500 detects overcurrent when heavy load is suddenly added?
    • C
      Carrie AndradeSep 3, 2025
      If the Inovance Controller detects overcurrent when a heavy load is suddenly added or during acceleration, increase the setting of F3-20 (overcurrent stall gain, default is 20) by 10 gradually, up to a maximum of 100. Also, decrease the setting of F3-18 (overcurrent stall actuating current, default is 150%) by 10% gradually, down to a minimum of 50%.

Summary

Safety Information

Safety Precautions

General safety guidelines for installation, operation, and maintenance.

During Installation

Safety warnings and precautions specifically for installation.

During Wiring

Safety warnings and precautions related to wiring the AC drive.

During Power-on

Safety warnings and precautions for powering on the AC drive.

During Running

Safety warnings and precautions when the AC drive is in operation.

During Maintenance

Safety warnings and precautions for maintenance activities.

During Repair

Safety warnings and precautions related to repairing the AC drive.

System Connection

MD500 System Connection Diagram

Shows a schematic diagram of the AC drive and its peripheral devices.

Installation and Wiring

Installation

Covers general installation requirements and procedures for the AC drive.

Mounting Clearance and Orientation

Specifies required clearance and orientation for mounting the drive.

Mounting in Cabinet

Details installation requirements for mounting the drive inside a cabinet.

Wiring

Details the wiring procedures and diagrams for the AC drive.

Functions of Main Circuit Terminals and Precautions

Explains the functions of main circuit terminals and associated precautions.

Control Circuit Terminal Arrangement

Details the arrangement and functions of control circuit terminals.

Panel Operation

LED Operating Panel

Details the features and operation of the LED-type programming panel.

View and Modify Function Parameters

Explains the procedure for navigating and modifying function parameters.

View Function Parameters

Describes different modes for viewing function parameters and how to switch.

External LCD Operating Panel

Describes the appearance and features of the optional external LCD operating panel.

Basic Operations and Trial Run

Quick Commissioning Guide

Step-by-step guide for initial setup and trial run of the AC drive.

Commissioning Flowchart

Outlines the overall commissioning process in a flowchart format.

Checklist Before Power-on

A checklist of items to verify before powering on the AC drive.

Motor Control

Details the different motor control modes available (SVC, FVC, V/F).

Start;Stop running command

Describes methods for controlling the start and stop operations of the drive.

Start the AC Drive

Explains different start modes for the AC drive.

Auto-tuning

Explains the motor auto-tuning methods for obtaining motor parameters.

Troubleshooting and Solutions

Safety Information

Safety precautions specifically related to troubleshooting and maintenance.

Troubleshooting During Trial Run

Common problems and solutions encountered during the trial run phase.

Fault Display

Explains how faults are displayed and provides general solutions.

Resetting Fault

Details the methods for resetting faults on the AC drive.

Faults and Diagnostics

Lists common faults, their causes, and possible solutions.

Symptoms and Diagnostics

Describes common symptoms and provides diagnostic steps for troubleshooting.

Routine Inspection and Maintenance

Routine Inspection

General guidelines and safety precautions for routine inspection.

Definition of Communication Data Address and Modbus Communication Protocol

Inovance MD500 Specifications

General IconGeneral
BrandInovance
ModelMD500
CategoryController
LanguageEnglish