Commissioning and Trial Run
‑111‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
FP‑03 7939 Individualized
parameter display
mode
Ones:
0: Not displayed
1: Displayed
Tens:
0: Not displayed
1: Displayed
0 ‑ Modifiable
in any states
FP‑04 7940 Parameter
modification property
0: Modification allowed
1: Modification prohibited
0 ‑ Modifiable
in any states
A0‑00 40960 Speed/Torque control
mode
0: Speed control
1: Torque control
0 ‑ Modifiable
only at stop
A0‑01 40961 Torque reference
source
0: Digital setting (A0‑03)
1: AI1
2: AI2
3: AI3
4: Reserved
5: Communication setting
(1000H)
6: Min. (AI1, AI2)
7: Max. (AI1, AI2)
0 ‑ Modifiable
only at stop
A0‑03 40963 Torque digital setting ‑2.000% to +2.000% 1.000 % Modifiable
in any states
A0‑04 40964 Torque filter time 0.000s to 5.000s 0.000 s Modifiable
in any states
A0‑05 40965 Speed limit digital
setting
‑120.0% to +120.0% 0.0 % Modifiable
in any states
A0‑07 40967 Torque acceleration
time
0.00s to 650.00s 1.00 s Modifiable
in any states
A0‑08 40968 Torque deceleration
time
0.00s to 650.00s 1.00 s Modifiable
in any states
A0‑09 40969 Speed limit setting
channel
0: A0‑05
1: Frequency source
0 ‑ Modifiable
in any states
A0‑10 40970 Speed limit offset 0.00–655.35 5.00 ‑ Modifiable
in any states
A0‑11 40971 Effective mode of
speed limit offset
0: Bidirectional offset
effective
1: Unidirectional offset
effective
0 ‑ Modifiable
only at stop
A0‑12 40972 Frequency
acceleration time
0.0s to 6500.0s 1.0 s Modifiable
in any states
A0‑13 40973 Frequency
deceleration time
0.0s to 6500.0s 1.0 s Modifiable
in any states
A0‑14 40974 Torque mode
switchover
0: No switchover
1: Switched to speed
mode upon stop
2: Target torque changed
to 0 upon stop
1 ‑ Modifiable
only at stop