Installation and Wiring
‑33‑
No.
Wiring Description
①
Connect the input terminals of the filter unit to the power input
terminals R, S, and T.
②
Connect the input grounding screw of the filter unit to the power
ground.
③
Connect the output terminals of the filter unit to the input terminals of
the power supply unit. It is recommended to use shielded cables.
④
Connect the output M4 grounding screw of the filter unit to the
grounding copper busbar.
⑤
Connect the M4 grounding screw of the power supply unit to the
grounding copper busbar.
⑥
Connect the M4 grounding screw of the drive unit to the grounding
copper busbar.
⑦
Connect the output side of the drive unit to the input side of the motor.
⑧
Connect the motor output grounding cable of the drive unit to the
grounding screw of the drive unit.
⑨
Ground the motor housing.
Note
In the preceding figure, the power supply unit is equipped with four dual‑axis drive units. In
the figure, only axis 1 of the rightmost drive unit is taken as an example to introduce the
wiring of the drive unit. The wiring for other drive units is similar.