Installation and Wiring
‑33‑
No.
Wiring Description
Connect the input terminals of the filter unit to the power input
terminals R, S, and T.
Connect the input grounding screw of the filter unit to the power
ground.
Connect the output terminals of the filter unit to the input terminals of
the power supply unit. It is recommended to use shielded cables.
Connect the output M4 grounding screw of the filter unit to the
grounding copper busbar.
Connect the M4 grounding screw of the power supply unit to the
grounding copper busbar.
Connect the M4 grounding screw of the drive unit to the grounding
copper busbar.
Connect the output side of the drive unit to the input side of the motor.
Connect the motor output grounding cable of the drive unit to the
grounding screw of the drive unit.
Ground the motor housing.
Note
In the preceding figure, the power supply unit is equipped with four dual‑axis drive units. In
the figure, only axis 1 of the rightmost drive unit is taken as an example to introduce the
wiring of the drive unit. The wiring for other drive units is similar.