Commissioning and Trial Run
‑96‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F8‑63 63551 Number of decimal
places for load speed
display
0: Zero
1: One
2: Two
3: Three
1 ‑ Modifiable
in any states
F8‑64 63552 7310H address data
unit
0: Frequency (Hz)
1: Speed (rpm)
0 ‑ Modifiable
only at stop
F9‑00 63744 AC drive overload
protection
0–1 0 ‑ Modifiable
in any states
F9‑01 63745 Motor overload
protection gain
0.20–10.00 1.00 ‑ Modifiable
in any states
F9‑02 63746 Motor overload pre‑
warning coefficient
50% to 100% 80 % Modifiable
in any states
F9‑06 63750 Output phase loss
detection before
startup
0: Disabled
1: Enabled
0 % Modifiable
in any states
F9‑07 63751 Detection of short‑
circuit to ground
0: No detection
1: Detected before power‑
on
1 ‑ Modifiable
only at stop
F9‑09 63753 Fault auto reset times 0–20 0 ‑ Modifiable
in any states
F9‑10 63754 DO action during fault
auto reset
0: Not act
1: Act
0 ‑ Modifiable
in any states
F9‑11 63755 Fault auto reset
interval
0.1s to 100.0s 1.0 s Modifiable
in any states
F9‑12 63755 Fault reset restart
interval
0s to 100.0s 1.0 s Modifiable
in any states
F9‑13 63757 STO state reset mode 0: Manual reset
1: Auto reset
0 ‑ Modifiable
only at stop
F9‑14 63758 1st fault type 0–99 Model
dependent
‑ Modification
prohibited
F9‑15 63759 2nd fault type 0–99 Model
dependent
‑ Modification
prohibited
F9‑16 63760 3rd (latest) fault type 0–99 Model
dependent
‑ Modification
prohibited
F9‑17 63761 Frequency upon 3rd
(latest) fault
‑ Model
dependent
‑ Modification
prohibited
F9‑18 63762 Current upon 3rd
(latest) fault
‑ Model
dependent
‑ Modification
prohibited
F9‑19 63763 Bus voltage upon 3rd
(latest) fault
‑ Model
dependent
‑ Modification
prohibited
F9‑20 63764 DI state upon 3rd
(latest) fault
‑ Model
dependent
‑ Modification
prohibited
F9‑21 63765 DO state upon 3rd
(latest) fault
‑ Model
dependent
‑ Modification
prohibited