Commissioning and Trial Run
‑95‑
Parameter
No.
Communication
Address
Parameter Name Setting Range Default Unit Property
F8‑44 63532 Detection value 2 of
any current reached
0.0% to 300.0% 100.0 % Modifiable
in any states
F8‑45 63533 Detection width 2 of
any current reached
0.0% to 300.0% 0.0 % Modifiable
in any states
F8‑46 63534 Timing function 0: Disabled
1: Enabled
0 ‑ Modifiable
only at stop
F8‑47 63535 Timing duration
source
0: Set by F8‑48
1: AI1
2: AI2
0 ‑ Modifiable
only at stop
F8‑48 63536 Timing duration 0.0–6500.0 min 0.0 min Modifiable
only at stop
F8‑49 63537 AI1 input voltage
lower limit
0.00–655.35 V 3.10 V Modifiable
in any states
F8‑50 63538 AI1 input voltage
upper limit
0.00–11.00 V 6.80 V Modifiable
in any states
F8‑51 63539 IGBT temperature
threshold
0°C to 100°C 75 °C Modifiable
in any states
F8‑52 63540 Cooling fan control 0: Runs in forward
direction during drive
running
1: Runs in forward
direction continuously
0 ‑ Modifiable
in any states
F8‑54 63542 Wakeup frequency Hibernating frequency (F8‑
56) to Max. frequency (F0‑
10)
0.00 Hz Modifiable
in any states
F8‑55 63543 Wakeup delay 0.0s to 6500.0s 0.0 s Modifiable
in any states
F8‑56 63544 Hibernating frequency 0.00 Hz to Wakeup
frequency (F8‑54)
0.00 Hz Modifiable
in any states
F8‑57 63545 Hibernating delay 0.0s to 6500.0s 0.0 s Modifiable
in any states
F8‑58 63546 Current running time
threshold
0.0–6500.0 min 0.0 min Modifiable
in any states
F8‑59 63547 Communication
address 2000H/2001H
switchover
0: General protocol
1: Specialized protocol
0 ‑ Modifiable
only at stop
F8‑60 63548 Emergency stop
deceleration time
0.0s to 6500.0s 0.0 s Modifiable
in any states
F8‑61 63549 Jog enabled by LED
panel
‑ 0 ‑ Modification
prohibited
F8‑62 63550 Load speed display
coefficient
0.0001–6.5000 1.0000 ‑ Modifiable
in any states